1.
J. oral res. (Impresa) ; 9(1): 72-80, feb. 28, 2020.
Artículo en Inglés | LILACS | ID: biblio-1151506

RESUMEN

Everyday use of denture cleansers to prevent microbial colonization on dentures can affect the properties of the denture base material. Limited literature is available on the effects of denture cleanser on reinforced resins. This study aimed to evaluate and compare the effect of denture cleanser on the flexural and impact strength of conventional and reinforced heat cure acrylic resins. Materials and Methods: Rectangular shaped specimens were prepared for flexural and impact strength as per ISO 1567. The denture base resins used included conventional, high impact, nylon fiber reinforced and glass fiber reinforced heat cure acrylic resins. They were further categorized into subgroups A and B depending on immersion in distilled water or denture cleanser (3.8% sodium perborate based). The flexural strength and impact strength of specimens were measured. The study design is a observational case-control study. SPSS version 25 statistical analysis software was used, and the STROBE statement checklist was followed. Results: The mean flexural strength was highest for glass fiber reinforced heat cure resin followed by conventional heat cure resin, high impact heat cure resin and nylon reinforced heat cure resin, respectively. The mean impact strength was highest for high impact heat cure resin followed by glass fiber reinforced heat cure resin, conventional heat cure resin, and nylon fiber-reinforced resin respectively.Conclusion: All the denture base resins tested exhibited a decrease in flexural and impact strength following use of a denture cleanser.


El uso diario de limpiadores para prótesis dentales para prevenir la colonización microbiana en las prótesis puede afectar las propiedades del material base de estas. Existe literatura limitada sobre los efectos de los limpiadores de prótesis sobre resinas reforzadas. Este estudio tuvo como objetivo evaluar y comparar el efecto de un limpiador de prótesis sobre la resistencia a la flexión y al impacto de las resinas acrílicas de curado con calor convencionales y reforzadas. Material y Métodos: Muestras de forma rectangular se prepararon para testear la resistencia a la flexión y al impacto según ISO 1567. Las resinas de base de prótesis utilizadas fueron resinas acrílicas convencionales, de alto impacto, y de curado térmico reforzadas con fibra de vidrio o nylon. Posteriormente se clasificaron en los subgrupos A y B según la inmersión en agua destilada o limpiador de prótesis (3,8% de perborato de sodio). Se midieron la resistencia a la flexión y la resistencia al impacto de las muestras. El diseño del estudio fue de un estudio observacional de casos y controles. Se utilizó el software de análisis estadístico SPSS versión 25, y se siguió la guía de la declaración STROBE. Resultado: La resistencia a la flexión fue más alta para la resina de curado por calor reforzada con fibra de vidrio seguida de la resina de curado por calor convencional, la resina de curado por calor de alto impacto y la resina de curado por calor reforzada con nylon, respectivamente. La resistencia al impacto fue más alta para la resina de curado por calor de alto impacto seguida de la resina de curado por calor reforzada con fibra de vidrio, la resina de curado por calor convencional y la resina reforzada con fibra de nylon, respectivamente. Conclusión: Todas las resinas de base de prótesis probadas exhibieron una disminución en la resistencia a la flexión y al impacto después del uso de un limpiador de prótesis.


Asunto(s)
Humanos , Bases para Dentadura , Limpiadores de Dentadura , Resistencia Flexional , Resinas Acrílicas , Prótesis Dental
2.
Acta fisiátrica ; 26(4): 209-214, Dez. 2019.
Artículo en Inglés | LILACS | ID: biblio-1129882

RESUMEN

Objetivo: Calcular o trabalho mecânico (W), aplicando o trabalho mecânico total (Wtot) e o trabalho segmentar (Wseg) como um novo recurso de avaliação complementar dos mecanismos de controle postural em sujeitos submetidos a perturbação motora e visual. Método: Dez voluntários adultos saudáveis do sexo masculino foram selecionados com idade 25,6 (± 2,26) anos, cuja altura era de 1,69 (± 0,25) m e peso corporal de 68,22 (± 0,25) kg. Os dados cinemáticos da extensão do tronco com os olhos abertos e vendados foram capturados com frequência de 200 Hz. Dessa forma, foi selecionado o intervalo pós-perturbação e o Wseg (tronco, cabeça, etc) e o trabalho mecânico total (Wtot) calculados, que foram obtidos por meio de energia mecânica total integral. Resultados: A análise estatística das informações foi feita pelo teste t student para dados emparelhados. Não houve diferença significativa (p<0,08) para a Wtot durante o intervalo pós-perturbação. Por outro lado, houve uma diferença significativa (p<0,05) no intervalo pós-perturbação de Wseg. Entretanto, houve diferenças significativas no intervalo (p<0,05). Esta diferença está relacionada com Wseg de cabeça (Wcabeça) e membros inferiores (Wperna e Wcoxa ) no intervalo pós-perturbação com intervalo inicial de [0. 60] ms e [0. 100] ms após a auto-perturbação. Conclusão: Essas diferenças encontradas em Wcabeça entre as duas condições podem estar associadas a modulações do sistema vestibulo-ocular-motor. Por outro lado, as diferenças encontradas em Wperna e Wcoxa podem ser associadas a mecanismos de ajuste somato-sensorial.


Objectie: Calculate the mechanical work (W), applying the total mechanical work (Wtot) and segmental work (Wseg) as a new complementary evaluation resource of the postural control mechanisms in subjects undergoing motor and visual disturbance. Methods: Ten healthy adult male volunteers were selected with ages 25.6 (±2.26) years, whose height was 1.69 (± 0.25) m and body weight was 68.22 (± 0.25) kg. Kinematic data of trunk extension with eyes open and blindfolded were captured with a frequency of 200 Hz. This way the post perturbation interval has been selected and the Wseg (i.e. trunk, head, etc) and the total mechanical work (Wtot) calculated, which were obtained by means of total integral mechanical energy. Results: The statistical analyzing of information was done by paired-data Student's t test. There has been no significant difference (p<0,08) for the Wtot during the post perturbation interval. On the other hand, there has been a significant difference (p<0.05) in the post perturbation interval of Wseg. However, there were significant differences in interval (p<0.05). This difference is related to Wseg of head (Whead) and lower limbs (Wleg and Wthigh ) in the post-perturbation interval with early range of [0. 60] ms and [0. 100] ms after the self-perturbation. Conclusion: These differences that were found in Whead between the two conditions can be associated with modulations of the vestibulo-ocular-motor system. On the other hand, the differences that were found in Wleg and Wthigh can be associated with somato-sensory adjustment mechanisms.


Asunto(s)
Equilibrio Postural , Fenómenos Mecánicos , Rehabilitación
3.
Dental press j. orthod. (Impr.) ; 21(6): 91-97, Sept.-Oct. 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-840196

RESUMEN

ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey’s tests. Results: Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Conclusions: Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.


RESUMO Objetivo: o objetivo deste estudo foi avaliar as forças de deflexão de fios ortodônticos retangulares em braquetes convencionais (MorelliTM) e autoligáveis ativos (In-Ovation RTM ) e passivos (Damon 3MXTM). Material e Métodos: foram utilizadas duas marcas comerciais (MorelliTM e GACTM) de fios de aço inoxidável e de níquel-titânio (NiTi), além do fio de NiTi com adição de cobre (OrmcoTM). Os espécimes foram montados em um dispositivo de simulação clínica especialmente desenhado para esse estudo e testado em uma máquina universal de ensaios Instron. Para o procedimento dos testes, a peça representativa do incisivo central superior direito foi movida no sentido vestibulolingual em ativações de 0 a 1 mm, com leituras da força liberada pela deflexão em 0,5; 0,8 e 1 mm, em uma velocidade constante de 2 mm/min. As forças interbraquetes com os fios de aço, de NiTi e NiTi com adição de cobre foram individualmente comparadas pelo teste de ANOVA a dois critérios, seguido pelo teste de Tukey. Resultados: houve menor liberação de forças nos braquetes convencionais, seguidos pelos braquetes autoligáveis ativos e passivos. Entre as marcas comerciais, somente houve diferença para o fio de NiTi, onde a marca MorelliTM apresentou maiores forças do que a GACTM. Conclusão: os braquetes promovem diferentes graus de forças de deflexão, sendo que os braquetes autoligáveis liberam as maiores forças.


Asunto(s)
Humanos , Alambres para Ortodoncia , Soportes Ortodóncicos , Acero Inoxidable , Análisis del Estrés Dental , Aleaciones , Fenómenos Mecánicos
4.
Rev. odontol. UNESP (Online) ; 45(5): 271-276, Sept.-Oct. 2016. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-798171

RESUMEN

Background: The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose: The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method: We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result: Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion: Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.


Contexto: O estudo do fenômeno de fadiga é essencial porque as falhas de implantes geralmente são causadas por este processo. Objetivo: O objetivo deste estudo foi analisar a resistência à fadiga de conjuntos de pilares retos e anatômicos que foram submetidos a cargas cíclicas. Material e método: Foram utilizados 37 implantes cone Morse e 37 pilares, divididos em dois grupos (n = 16: pilares retos, n = 21: pilares anatômicos). Os conjuntos foram submetidos à carga cíclica (5.000.000) usando o equipamento servo-hidráulico. Três conjuntos de cada grupo foram submetidos a testes de flexão para determinar a resistência de carga máxima, o que serviu de parâmetro para comparação dos testes cíclicos. Foram avaliados número de ciclos, carga e momento de flexão. Resultado: Dos 31 pilares ciclicamente testados, 17 (54,8%) fraturaram em menos de 5 milhões de ciclos; 8 (25,8%) destes eram pilares retos, e 9 (29%) eram anatômicos. Um total de 14 amostras (45,2%) resistiu à carga cíclica. De acordo com o teste exato de Fisher, não houve diferença entre os grupos quanto à fratura. Conclusão: Apesar dos pilares retos terem maior carga média e momento de flexão que os anatômicos, os dois tipos de pilares apresentaram desempenho semelhante quanto a resistência à fratura in vitro.


Asunto(s)
Técnicas In Vitro , Implantes Dentales , Fenómenos Mecánicos , Resistencia Flexional
5.
Rev. bras. ortop ; 51(1): 29-35, Jan.-Feb. 2016. tab, graf
Artículo en Portugués | LILACS | ID: lil-775643

RESUMEN

This study investigated removal of a force-closed stem, done in order to improve acetabular exposure during revision, with reinsertion afterwards. It is unknown how much this procedure modifies the stem/cement interface. METHODS: Three tapered stem models were implanted into composite femurs. Strain gauges were embedded in the medial aspect of the cement mantle and in several positions on the outer surface of the femurs. The deformation was measured during static loading, which was applied at two different times: after implantation and after one million loading cycles, followed by stem removal and reinsertion. The t test was performed. The differences in deformation were compared (at p ≤ 0.05) between the two static loading times and among the three stem designs. RESULTS: No significant differences in deformation were found after the two loading times for the three models. No significant differences in the initial deformations of the three models were found for most of the gauges attached to the femurs. CONCLUSIONS: Reinsertion of the force-closed stem does not alter the load transmission from the stem to the cement and to the surface of the femur, even after one million loading cycles.


Estudo da remoção de haste do tipo force-closed e a sua reinserção posterior para aumentar a exposição do acetábulo durante a revisão. Não é conhecido o quanto esse procedimento modifica a interface haste/cimento. MÉTODOS: Três modelos de hastes afiladas foram implantadas em fêmures compósitos. Extensômetros de deformação foram embebidos no aspecto medial do manto de cimento e em diversas posições sobre a superfície externa dos fêmures. As deformações foram medidas durante cargas estáticas, as quais foram aplicadas em dois diferentes momentos: após a implantação e após um milhão de ciclos de carga, seguido pela remoção e reinserção. O teste t foi feito. As diferenças entre as deformações foram confrontadas com p ≤ 0,05 entre os dois momentos de carga estática e entre os três projetos de hastes. RESULTADOS: Não foram encontradas diferenças significativas nas deformações após os dois momentos de carga para os três modelos. Não foram encontradas diferenças significativas nas deformações iniciais dos três modelos para a maioria dos extensômetros aderidos aos fêmures. CONCLUSÕES: A reinserção de haste do tipo force-closed não altera a transmissão de carga da haste para o cimento e para a superfície do fêmur, mesmo após um milhão de ciclos.


Asunto(s)
Humanos , Artroplastia de Reemplazo de Cadera , Fenómenos Mecánicos , Diseño de Prótesis
6.
Bauru; s.n; 2016. 120 p. tab, ilus, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-881807

RESUMEN

O objetivo desse estudo foi realizar a caracterização do cimento resinoso autoadesivo RelyX U200 aditivado de nanotubos de dióxido de titânio (nt-TiO2) em diferentes concentrações (0,3, 0,6, e 0,9% em peso) quanto às suas propriedades físico-químicas, mecânicas e biológica. Duas condições de polimerização foram analisadas: autopolimerizável (grupos: AC, A03, A06 e A09) e dual (grupos: DC, D03, D06 e D09). Para análise do grau de conversão foi utilizada a espectroscopia de infravermelho com transformada de Fourier com registro do espectro nos tempos de 3, 6, 9, 12 e 15 minutos. Os picos das bandas de comprimento de onda de 1638 cm-1 e de 1608 cm-1 foram identificados para cálculo do grau de conversão. Os dados foram submetidos à ANOVA de medidas repetidas seguido de comparações múltiplas de Tukey (=0,05). A análise de sorção e solubilidade foi realizada por meio da confecção de discos de cimento resinoso (10 mm ø × 2 mm) (n=8) monitorados quanto à sua massa depois de ciclos de hidratação/desidratação. A resistência à flexão em 3 pontos e módulo de elasticidade foram mensurados por meio de barras (2 × 2 × 25 mm) de cimento resinoso (n=10) levadas à máquina universal de ensaios. Para análise de Dureza Knoop utilizou-se microdurômetro com carga de 50g /10 segundos. Nos discos de cimento resinoso de 10 mm ø × 2 mm foram realizadas 5 endentações equidistantes 0,5mm e medidas em aumento de 50×. Para resistência de união ao cisalhamento, sobre discos de zircônia sinterizados foi aplicado o cimento resinoso (n=10) nas dimensões de 3 mm ø × 2 mm. Por meio de dispositivo foram levados à máquina universal de ensaios. Os dados encontrados de sorção e solubilidade e de cada propriedade mecânica foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Exceto para resistência ao cisalhamento que se utilizou o teste de comparação de Fischer (=0,05). Para viabilidade celular (n=8) foi realizado teste de MTT apenas na condição dual. Os grupos estudados foram: DC, D03, D06, D09, CP (controle positivo), CN (controle negativo). Após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de ELISA. Os dados foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Os resultados mostraram que a adição de nt-TiO2, independente da concentração, aumentou os valores de grau de conversão do cimento resinoso para a condição autopolimerizável e dual em todos os tempos estudados. Já para sorção e solubilidade não houve influência nos resultados da concentração de nanotubos inseridos e da condição de polimerização. Para resistência flexural, a adição de nt-TiO2 nas concentrações de 0,3% (A03) e 0,9% (A09) resultou em dados similares ao controle na condição dual (DC). O valor médio de módulo de elasticidade aumentou com a adição de 0,9% (A09), similar a todos os grupos da condição dual, em que adição de nt-TiO2 não influenciou os resultados. A adição de 0,6% (A06 e D06) e 0,9% (A09 e D09) de nt-TiO2 ao cimento aumentou os valores de dureza quando comparado aos grupos controle (AC e DC). Para resistência de união ao cisalhamento, a concentração de 0,3% de nt-TiO2 (A03 e D03) aumentou os valores quando comparado aos grupos A06, D06, A09 e D09 porém sem diferença para os grupos controle (AC e DC). Para viabilidade celular no período de 24h, os grupos D03, D06 e D09 obtiveram resultado similar ao grupo CP, já o grupo DC apresentou valores de absorbância inferiores ao CP, usado como parâmetro de comparação. Em 48 e 72h, todos os grupos experimentais não demonstraram diferença significativa em comparação ao grupo CP. O grupo CN apresentou diferença para os demais em todos dos tempos estudados. A adição de nt-TiO2 ao cimento resinoso autoadesivo representa uma estratégia promissora para potencializar suas propriedades físico-químicas e mecânicas sem prejuízo das propriedades biológicas.(AU)


The aim of this study was to characterize the self-adhesive resin cement RelyX U200 additive, titanium dioxide nanotubes (nt-TiO2), at different concentrations (0.3%, 0.6%, and 0.9% by weight) and to determine their physicochemical, mechanical and biological properties. Two polymerization conditions were analyzed: self-curing (groups AC, A03, A06 and A09) and dual-curing (groups DC, D03, D06 and D09). To analyze the conversion degree, Fourier transform infrared spectroscopy was used, and the spectrum was recorded at 3, 6, 9, 12 and 15 minutes. The peaks of the wavelength bands, 1638 cm-1 and 1608 cm-1, were identified to calculate the degree of conversion. The data were subjected to a repeated-measures ANOVA followed by a Tukey multiple-comparison test (=0.05). The sorption and solubility analysis was performed by making resin-cement discs (10 mm ø × 2 mm) (n=8) and monitoring their masses after the hydration/dehydration cycles. The 3-point flexural strength and the modulus of elasticity of resin-cement bars (2 × 2 × 25 mm) (n=10) were measured using a universal testing machine. The Knoop microhardness was analyzed with a load of 50 g and a time of 10 seconds. On each resin cement disc, 5 equidistant indentations of 0.5 mm were made, and the measures were increased by 50×. To test bonding shear strength, resin cement was applied to sintered zirconia discs (3 mm ø × 2 mm) (n=10). The bonded discs were then taken to the universal testing machine. Their sorption, solubility and each mechanical property were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The shear strength was submitted to a Fischer comparison test (=0.05). To test cell viability (n=8), a MTT assay was performed using only the dual-curing condition. The studied groups were: DC, D03, D06, D09, CP (positive control) and CN (negative control). After 24, 48 and 72 hours, the absorbance levels were analyzed using an ELISA spectrophotometry reader. The data were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The results showed that the addition of nt-TiO2, regardless of concentration, increased the conversion degree values for the self-curing resin cement and for the dual-curing at all times studied. The sorption and solubility were not influenced by the concentration of the nanotubes or the polymerization condition. Regarding flexural strength, the addition of the nt-TiO2 in concentrations of either 0.3% (A03) or 0.9% (A09) resulted in data similar to those in the dual-curing control (DC) condition. The average modulus of elasticity increased with the addition of 0.9% nt-TiO2 (A09), and as with all the groups in the dual-curing condition, the addition of nt-TiO2 did not affect the results. The addition of either 0.6% (A06 and D06) or 0.9% (A09 and D09) of nt-TiO2 cement increased hardness values relative to the control groups (AC and DC). The group with a 0.3% concentration of nt-TiO2 (A03 and D03) showed higher bonding shear strength values than several of the groups with higher concentrations (A06, D06 and D09), but the A09 group had no difference relative to either control group (AC or DC). For cell viability in the 24-h period, the D03 D06 and D09 groups achieved a result similar to that of the CP group with significant difference to the DC group that had lower absorbance values. At the benchmarks of 48 and 72 h, and only the CN group showed a significant difference compared to others. The addition of nt-TiO2 is a promising strategy for improving the physical-chemical and mechanical properties without prejudice the biological properties.(AU)


Asunto(s)
Animales , Ratones , Nanotubos/química , Polimerizacion , Cementos de Resina/química , Auto-Curación de Resinas Dentales/métodos , Titanio/química , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Ensayo de Inmunoadsorción Enzimática , Fibroblastos/efectos de los fármacos , Pruebas de Dureza , Ensayo de Materiales , Fenómenos Químicos , Reproducibilidad de los Resultados , Cementos de Resina/farmacología , Resistencia al Corte , Espectroscopía Infrarroja por Transformada de Fourier , Factores de Tiempo , Titanio/farmacología
7.
Rev. bras. ortop ; 50(6): 686-693, Nov.-Dec. 2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-769995

RESUMEN

Subtle differences in stem design can result in different mechanical responses of the total hip arthroplasty. Tests measuring migration of the stem relative to the femur, as well as the strains in the cement mantle and on the femur can detect different mechanical behavior between stems. Methods: In this article, conical, double and triple tapered stems were implanted in composite femurs and subjected to static and cyclic loads. Stems differed mainly on taper angle, calcar radius and proximal stiffness. Stem migration and strains on the femur and in the cement mantle were achieved. Results: Significant differences (p < 0.05) were noted in the permanent rotation between double and triple tapers, in the strains on the proximal medial femur between triple and both conical and double tapers, and in the strains on the lateral proximal femur between double tapers and both conical and triple tapers. Conclusion: The proposed mechanical tests were able to detect significant differences in the behavior of these resembling stems. Stem proximal stiffness and the calcar radius of the stem influence its rotational stability and the strain transmission to the femur.


Diferenças sutis no projeto da haste podem resultar em diferentes respostas mecânicas da artroplastia total do quadril. Testes que meçam a migração da haste em relação ao fêmur, bem como as deformações no cimento e no fêmur, podem salientar as diferenças entre diferentes projetos de hastes. MÉTODOS: Neste artigo foram implantadas hastes cônicas, hastes duplamente afiladas e triplamente afiladas em fêmures compósitos e submetidas a cargas estáticas e cíclicas. As hastes diferenciaram-se principalmente em relação aos afilamentos, ao raio do calcar e à rigidez proximal. A migração das hastes e as deformações tanto no fêmur quanto no cimento foram medidas. RESULTADOS: Foram observadas diferenças significativas (p < 0,05) na rotação permanente entre as hastes duplamente e triplamente afiladas, nas deformações do nível proximal medial do fêmur entre as hastes triplamente afiladas e ambas cônicas e duplamente afiladas e nas deformações do nível proximal lateral do fêmur entre as hastes duplamente afiladas e ambas cônicas e triplamente afiladas. CONCLUSÃO: Os ensaios mecânicos propostos foram capazes de produzir diferenças significativas no comportamento dessas hastes semelhantes. A rigidez proximal da haste e o raio do calcar influenciam a estabilidade rotacional e a transmissão de deformação da haste ao femur.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fenómenos Biomecánicos , Diseño de Prótesis
8.
Rev. odontol. UNESP (Online) ; 44(2): 67-73, Mar-Apr/2015. tab, ilus
Artículo en Portugués | LILACS | ID: lil-746236

RESUMEN

Objetivo: Analisar a resistência à fratura por fadiga dos conjuntos implante-pilar, nos tipos reto e angulado, submetidos a cargas cíclicas similares às mastigatórias. Material e método: Foram utilizados 32 implantes (3,75 × 11 mm) com sistema cone Morse e 32 pilares, separados em dois grupos: pilares retos e angulados (n=16) (Neodent, Curitiba, PR, Brasil). Os conjuntos foram submetidos a testes cíclicos em equipamento servo-hidráulico, fixando-se o número de ciclos em cinco milhões. Foram avaliados: número de ciclos, carga e momento de força das amostras. O Teste de Fisher e o Teste ANOVA foram aplicados (p<0,005). Amostras fraturadas foram analisadas em microscopia eletrônica de varredura (MEV). Resultado: Dos pilares retos, quatro resistiram ao número de ciclos estabelecidos, suportando cargas entre 470 N e 510 N. No grupo dos angulados, nove amostras resistiram a cargas entre 570 N e 890 N. Quanto às amostras fraturadas abaixo do número de ciclos, no grupo pilar reto, nove fraturaram com cargas entre 470 N e 630 N. No grupo pilar angulado, cinco amostras fraturaram com cargas entre 760 N e 890 N. Foi calculado, para cada conjunto implante-pilar, o momento de força (Médias: Grupo reto - 4.335,2 Nmm, Grupo angulado - 3.923,3 Nmm). Conclusão: Os dois tipos de pilares (retos e angulados), em condições in vitro, comportaram-se estatisticamente de forma semelhante, sendo aceita a hipótese nula de que não há diferença de resistência à fratura entre os grupos.


Objective: The aim of this study was to verify the fatigue fracture resistance of the implant-abutment joint, in straight and angled types, subject to cyclic loads similar to chewing. Material and method: It was used 32 implants system (3.75 × 11mm) with Morse taper and 32 abutment, divided in two groups: abutment straight and angled (n = 16) (Neodent, Curitiba, PR, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. It was evaluated the number of cycles, load and moment force of the samples. The Fisher test and ANOVA were applied (p<0,005). Fractured samples were analyzed in the scanning electron microscopy (SEM). Result: Straight abutment, four resisted the cycles number established, supporting loads between 470N and 510N. Angled abutment: nine resisted to loads between 570N and 890N. Regarding the fractured samples below the number of cycles, in the straight abutment, nine fractured with loads between 470N and 630N. In the angled abutment, five fractured with loads ranging from 760N and 890N. The moment of the force was calculated for each joint implant-abutment (Averages: Straight Group - 4335,23Nmm, angled Group - 3923,37Nmm). Conclusion: Two types of abutments (straight and angled), in vitro conditions, statistically behaved similarly, and accepts the null hypothesis that there is no difference in fracture resistance between groups. .


Asunto(s)
Microscopía Electrónica de Rastreo , Análisis de Varianza , Implantación Dental Endoósea , Fenómenos Mecánicos , Resistencia Flexional , Titanio , Técnicas In Vitro , Rehabilitación Bucal
9.
Bauru; s.n; 2014. 137 p. ilus, tab, graf.
Tesis en Portugués | LILACS | ID: lil-751576

RESUMEN

PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios, demonstrou que a mesma foi crescente em todos...


OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was moved in the buccal-lingual direction, and values of resistance generated for 3, 2, 1 and 0.5mm deflections, at a constant speed of 2mm/min, were registered. Data were subjected to Oneand Two-way ANOVA; since significant differences were observed, comparative analysis of mean values was performed by Tukey's post hoc test (p<0.05). RESULTS: Elastic deflection results showed that deactivation force increased with increase in the diameter of the wires and deflection in the different brackets evaluated. For the combinations of the different types of brackets with the Nitinol wires, it was found that self-ligating brackets were those with the most similar results to each other, which decreased as the deflection was decreased. For Mini Diamond, Spirit and Inspire ICE conventional brackets there was no pattern for any of the deflections studied. CONCLUSIONS: Strength values evaluation according to gradual increase in the diameter and the deflection of the wires showed that it increased in all evaluated brackets. Self-ligating brackets were those which presented the most consistent and...


Asunto(s)
Soportes Ortodóncicos , Alambres para Ortodoncia , Análisis de Varianza , Elasticidad , Ensayo de Materiales , Docilidad , Valores de Referencia , Resistencia a la Tracción , Factores de Tiempo
10.
Bauru; s.n; 2014. 137 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-867107

RESUMEN

PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios, demonstrou que a mesma foi crescente em todos...


OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was moved in the buccal-lingual direction, and values of resistance generated for 3, 2, 1 and 0.5mm deflections, at a constant speed of 2mm/min, were registered. Data were subjected to Oneand Two-way ANOVA; since significant differences were observed, comparative analysis of mean values was performed by Tukey's post hoc test (p<0.05). RESULTS: Elastic deflection results showed that deactivation force increased with increase in the diameter of the wires and deflection in the different brackets evaluated. For the combinations of the different types of brackets with the Nitinol wires, it was found that self-ligating brackets were those with the most similar results to each other, which decreased as the deflection was decreased. For Mini Diamond, Spirit and Inspire ICE conventional brackets there was no pattern for any of the deflections studied. CONCLUSIONS: Strength values evaluation according to gradual increase in the diameter and the deflection of the wires showed that it increased in all evaluated brackets. Self-ligating brackets were those which presented the most consistent and...


Asunto(s)
Soportes Ortodóncicos , Alambres para Ortodoncia , Análisis de Varianza , Elasticidad , Ensayo de Materiales , Docilidad , Valores de Referencia , Resistencia a la Tracción , Factores de Tiempo
11.
Int. j. odontostomatol. (Print) ; 7(2): 315-318, Aug. 2013. ilus
Artículo en Inglés | LILACS | ID: lil-690520

RESUMEN

The use of indirect restorations have increased in tooth with great dental destruction due to their physical and mechanical properties that bestow higher durability than other type of restoration. The aim of the study was to compare the flexural resistance of four indirect restoration materials (composite Filtek P60; ceromers Adoro and Ceramage; ceramic IPS e.max), by testing the hypothesis that ceramic has a higher flexural resistance than ceromer and composite. Ten bars of each material were made following the 27, 53, 69 ANSI/ADA norms and the manufacturer's instructions. The flexural resistance was obtained by a three-point test using the Instron machine at a loading rate of 1 mm/min. The resistance was calculated in MPa and the results were statistically analyzed through ANOVA y Scheffé tests. Filtek P60 flexural resistance is significantly higher than Ceramage. Adoro flexural resistance is significantly lower than all the other materials. It is necessary to make absolutely clear that the research was executed in vitro, whereby its resistances may differ than in mouth because of the cementation and the "mono-block" formation. Through the research it was determined that Filtek P60 is significantly higher than Ceramage, and that Adoro is significantly less than all the other compared materials regarding flexural resistance; whereby the raised hypothesis is nullified.


El uso de restauraciones indirectas ha aumentado en los dientes con gran destrucción coronaria debido a sus propiedades físicas y mecánicas que confieren mayor durabilidad que otro tipo de restauraciones. El objetivo del estudio fue comparar la resistencia a la flexión de cuatro materiales de restauración indirecta (composite Filtek P60; cerómeros Adoro y Ceramage; cerámica IPS e.max), probando la hipótesis de que la cerámica tiene una mayor resistencia a la flexión que el cerómero y el composite. Diez barras de cada material fueron realizadas de acuerdo a las normas ANSI/ADA 27, 53 y 69 y siguiendo las instrucciones del fabricante. La resistencia a la flexión se obtuvo mediante una prueba de tres puntos utilizando una máquina Instron a una velocidad de carga de 1 mm/min. La resistencia se calculó en MPa y los resultados fueron analizados estadísticamente mediante ANOVA y una prueba de Scheffe. La resistencia a la flexión de Filtek P60 es considerablemente mayor que Ceramage. La resistencia a la flexión de Adoro es significativamente más baja que todos los otros materiales. Debe quedar absolutamente claro que la investigación fue realizada in vitro, por lo que la resistencia de los materiales podría ser diferente que en boca debido a la cementación y la formación de un "mono-bloque". A través de la investigación, se determinó que la resistencia a la flexión de Filtek P60 es significativamente superior a Ceramage, y la de Adoro es significativamente inferior a todos los demás materiales en comparación; con lo que la hipótesis planteada es anulada.

12.
Bauru; s.n; 2012. 154 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-673682

RESUMEN

PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade...


OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.


Asunto(s)
Humanos , Níquel/química , Alambres para Ortodoncia , Titanio/química , Módulo de Elasticidad , Ensayo de Materiales , Maloclusión/terapia , Estadísticas no Paramétricas
13.
Bauru; s.n; 2012. 154 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-866210

RESUMEN

PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade...


OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.


Asunto(s)
Humanos , Níquel/química , Alambres para Ortodoncia , Titanio/química , Módulo de Elasticidad , Ensayo de Materiales , Maloclusión/terapia , Estadísticas no Paramétricas
14.
J. Health Sci. Inst ; 27(1): 48-51, jan.-mar. 2009. tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-873986

RESUMEN

Introdução - A eficiência e a durabilidade de protetores bucais para esporte dependem diretamente da forma com que são usados, pois sempre se apresentam em condições básicas de presença ou ausência de saliva. Para observar se essa condição de uso interfere em suas propriedades mecânicas este trabalho observa através de modelo experimental de arcos dentais obtidos em epóxi, acoplados a uma máquina universal de ensaios Kratos programada para movimento de compressão, o comportamento mecânico de protetores bucais para esporte, confeccionados em copolímero de etileno e acetato de vinila - EVA, posicionados no arco superior. Material e Métodos - Foram formados dois grupos de estudo: protetores bucais secos e protetores bucais saturados em saliva artificial, sendo estes últimos obtidos através de análise de saturação com o auxílio de balança analítica para observação de ganho de massa. As propriedades mecânicas observadas foram força máxima e energia absorvida. Resultados - Os resultados foram submetidos a análise estatística t-student (p < 0,05). Observou-se que no grupo dos protetores bucais saturados com saliva houve redução da força máxima (p = 0,00) devido a plastificação do material, responsável pela redução das forças intermoleculares ocasionando maior deformabilidade do protetor atestado pelo aumento da energia absorvida (p = 0,05) quando comparado ao grupo dos protetores secos. Conclusão - Conclui-se que a presença da saliva altera o comportamento mecânico do protetor bucal confeccionado em EVA tornando-o mais dúctil, portanto diminuindo a probabilidade de fraturas dentais e/ou lesões em tecidos circunvizinhos


Asunto(s)
Protectores Bucales , Saliva Artificial/química , Ensayo de Materiales/métodos , Técnicas In Vitro , Polietilenos , Polivinilos/química , Interpretación Estadística de Datos
15.
J. Health Sci. Inst ; 27(1)jan.-mar. 2009. tab
Artículo en Portugués | LILACS | ID: lil-545267

RESUMEN

Introdução - A eficiência e a durabilidade de protetores bucais para esporte dependem diretamente da forma com que são usados, pois sempre se apresentam em condições básicas de presença ou ausência de saliva. Para observar se essa condição de uso interfere em suas propriedades mecânicas este trabalho observa através de modelo experimental de arcos dentais obtidos em epóxi, acoplados a uma máquina universal de ensaios Kratos programada para movimento de compressão, o comportamento mecânico de protetores bucais para esporte, confeccionados -m copolímero de etileno e acetato de vinila ? EVA, posicionados no arco superior. Material e Métodos - Foram formados dois grupos de estudo: protetores bucais secos e protetores bucais saturados em saliva artificial, sendo estes últimos obtidos através de análise de saturação com o auxilio de balança analítica para observação de ganho de massa. As propriedades mecânicas observadasforam força máxima e energia absorvida. Resultados - Os resultados foram submetidos a analise estatística t-student (p < 0,05). Observou-se que no grupo dos protetores bucais saturados com saliva houve redução da força máxima (p = 0,00) devido a plastificação do material, responsável pela redução das forças intermoleculares ocasionando maior deformabilidade do protetor atestado pelo aumento da energia absorvida (p = 0,05) quando comparado ao grupo dos protetores secos. Conclusão - Conclui-se que a presença da saliva altera o comportamento mecânico do protetor bucal confeccionado em EVA tornando-o mais dúctil, portanto diminuindo a probabilidadede fraturas dentais e/ou lesões em tecidos circunvizinhos.


Introduction - The efficiency and durability of mouth protectors for sports depend directly on the way they are used, mainly because of their frequent exposure to saliva. To analise if this condition of use affects their mechanical properties, this paper observes, through the use of an experimental model made of epoxy, connected to an universal testing machine Kratos programmed to compress, the mechanical behaviour of mouth protectors for sports, made of ethylene and vinyl acetate copolymer - EVA, positioned on the superior arch. Two groups of study were created: dry mouth protectors and artificial saliva saturated mouth protectors, the second of which was analised with the use of an analitical balance to measure the level of saturation through the gain of mass.The mechanical properties observed were maximal strength and absorbed energy. The results were submitted to t-student statistical analisis method (p < 0,05). It was observed that, in the saturated mouth protectors group, the maximal strength diminished (p = 0,00) due to the material plastification, that caused a reduction in the intermolecular force and consequently a bigger deformation of the protector, confirmed by the increase in the absorbed energy (p = 0,05) when compared to the dry protectors group. It was concluded that the presence of saliva changes the mechanical behaviour of the mouth protector made of EVA, making it more flexible and reducing the probability of dental fractures and/or injuries on adjacent tissues.


Asunto(s)
Polivinilos/análisis , Polivinilos/síntesis química , Protectores Bucales , Saliva Artificial/síntesis química , Ensayo de Materiales/métodos , Polímeros/análisis , Polímeros/síntesis química